Pass 71
2026-11-04 17:35 PST (2026-11-05T01:35:35Z UTC) · commit 8d17402 (8d17402bba0d6178daa567436f191a0f6f911b15)
ADOPTED
heal-all on the stubbed board (58 nets): only 8 groups connected in 1101 s (APD_K x3, HV_FBX, I2C_SCL/SDA, HV_SHDN, TMP_ALERT) vs 93 STILL isolated — and violations REGRESSED 2 -> 32 (30x APD_K copper vs GND pour; groups 163 -> 156, nets 59). Root cause found in hw/router.py: the A* grid is still sized for the pre-expansion board (W,H = 400,320 = 100x80 mm, cell_of clamps y to [0,80]) — every strip pad/track (y<0) crushes onto grid row 0, so strip searches tested phantom geometry along the old field’s congested north edge and emitted vias at y 0.6-2.1 where no HV keepout exists. The expansion’s open space was invisible to the router for passes 65-71. Fix next: grid 400x440 with OY=-30 in router.py/router6.py.
| Nets fully routed | not recorded |
| Pins failed | not recorded |
| Clearance violations | 32 |
| Unconnected nets | 59 |
| Audit verdict | FAIL |
Routes — all copper layers and each layer
F.Cu In1.Cu In2.Cu B.Cu
Top
Bottom
heal log: results/heal-all.log; audit: results/audit-exp7.txt (violations itemized: 30 APD_K-vs-zone + 2 justified D1)